High sensitivity 4-core positioning water leak detector rope. Pinpoints leak location to within 1 m. For large data centres, server rooms, and facility water protection.
The positioning water leak detector rope uses a 4-core construction with precision resistance-per-metre calibration to enable the connected controller to calculate the exact distance to the leak -- accurate to within 1 metre. High sensitivity detection ensures that even minor water presence (small drops or condensation pooling) triggers an immediate alarm, long before significant water damage can occur. Essential for large data centres, raised-floor environments, and critical facilities where rapid fault location is essential to minimise downtime.
| Parameter | Specification |
|---|---|
| Type | Positioning Water Leak Detection Rope |
| Cores | 4-core sensing configuration |
| Location Accuracy | ≤1 m |
| Sensitivity | High sensitivity -- detects small water droplets |
| Standard Lengths | 10 m, 20 m, 50 m, 100 m, 200 m (custom) |
| Jacket Material | PVC / PE |
| Diameter | ~6 mm (4-core) |
| Response Time | <3 seconds |
| Temperature Range | -10°C to +70°C |
Specify rope length and positioning controller for a complete system quote: sales@rovcable.com -- Shanghai Kabel Intelligence Technology Co., Ltd.
The 4-core rope has a precisely controlled resistance per metre of length. When water bridges the sensing conductors at a specific location, the controller measures the resistance change and calculates the distance (D = R_leak / resistance_per_metre). This gives a leak location accurate to within 1 m on cable runs up to 200 m.
Our positioning rope is calibrated to standard resistance-per-metre values compatible with most industry-standard positioning controllers (including popular brands). Confirm the resistance specification of your controller with our technical team before ordering to ensure compatibility.
Yes. The rope is flexible and can be routed around corners, under equipment, and along complex floor plans. Maintain a minimum bend radius of 5x the rope diameter. Avoid sharp kinks which can affect the resistance calibration and cause false alarms.
Technical parameter
|
Cable material: |
Conductive polyethylene + alloy wire |
|
Core resistance: |
13.00 Ohm/meter |
| Length | any length can be cut |
|
Connector |
can be customized |
|
Cable color |
yellow, blue(You can choose) |
|
Cable mass: |
38g/meter |
|
Cable diameter: |
6.0mm |
|
Exposure temperature: |
85℃ (maximum) |
|
Certification: |
CE,FCC,ROHS |