rovconnector
Sales service hotline: Sales@rovcable.com
Current location: Home > Products > Aviation plug Series

4mm Non-Positioning Water Leak Detection Rope | Sensing Cable

Published on:2026-05-24 Click:16

4mm Non-Positioning Water Leak Detection Rope | Sensing Cable

4mm non-positioning water leak detection rope sensing cable. Detects water presence along full cable length. PVC jacket, for data centres, server rooms, and facility protection.

Product introduction

4mm Non-Positioning Water Leak Detection Rope Sensing Cable

The 4mm non-positioning water leak detection rope is a sensing cable that detects the presence of water anywhere along its full length. When water contacts the sensing conductors, the electrical resistance changes and triggers an alarm in the connected leak detection controller. At 4mm diameter, this sensing rope is compact and discreet, suitable for deployment under raised floors, around server racks, under water tanks, and along pipe runs in data centres, server rooms, and critical facilities.

Parameter Specification
Type Non-Positioning Water Leak Detection
Diameter 4 mm
Detection Full-length (no location data)
Sensing Principle Resistance change on water contact
Jacket Material PVC
Standard Lengths 10 m, 20 m, 50 m, 100 m (custom)
Controller Compatibility Matches standard leak detection controllers
Temperature Range -10°C to +70°C
Response Time <3 seconds

Key Applications

  • Data centre raised-floor water leak monitoring
  • Server room and telecommunications room protection
  • Under CRAC/CRAH unit monitoring
  • Water tank and pipe run leak detection
  • Museum, archive, and storage room protection

Order water leak detection rope in custom lengths: sales@rovcable.com -- Shanghai Kabel Intelligence Technology Co., Ltd.

Frequently Asked Questions

What is the difference between non-positioning and positioning leak detection rope?

Non-positioning rope detects that a leak exists somewhere along its length but cannot indicate exactly where. Positioning rope (see our n=811 product) uses a resistance-per-unit-length measurement to calculate the distance to the leak, enabling rapid location of the fault. For small rooms where any alarm is sufficient, non-positioning is cost-effective; for large data centres where rapid repair is critical, positioning rope is recommended.

Can the rope be reused after a water detection event?

Yes. After detecting water, dry the rope thoroughly (typically with compressed air or a dry cloth) and allow it to air-dry fully. Most detection events do not damage the rope, and it can be reused indefinitely. Replace if the jacket is physically damaged.

What controller do I need for this rope?

Any standard 2-wire or 4-wire leak detection controller compatible with resistance-based sensing ropes will work. We can supply compatible controllers -- contact us with your installation details for a controller recommendation.

                               Technical parameter

Cable material:

Conductive polyethylene + alloy wire

length:

Any length can be cut

Connector:

3.5mm

Cable color:

White

Cable mass:

20g/m

Breaking strength:

35 kg

Cable diameter:

4.0mm

Exposure temperature:

85℃ (maximum)

Certification:

CE,FCC,ROHS

Applications

  • Quick-connect underwater systems requiring aviation-style push-pull coupling
  • Marine instrumentation, underwater sensor networks and portable field equipment
  • LEMO-compatible connector replacements for existing subsea installations
  • Underwater camera systems, ROV control panels and deck equipment connectivity
  • Bench testing, workshop equipment and temporary subsea sensor deployments

Customization Options

  • Custom cable assemblies with specified connector-cable termination method
  • Alternative shell plating and contact plating materials available
  • Customer-specified pin configurations and cable entry orientations
  • Custom branding, labeling and packaging options for OEM customers